Skip to main content
Siemens 3VA2110-7MS32-0HL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-7MS32-0HL0 SENTRON MCCB, 100 A, 330 kA at 24

MPN3VA2110-7MS32-0HL0

Siemens SENTRON 3VA2110-7MS32-0HL0, Molded case circuit breaker, 3-pole, 100 A, 330 kA at 240 V, 242 kA at 415 V, starter protection, ETU310M release, shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2110-7MS32-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionStarter protection
Basic switch (supplied) ref.3VA2110-7MS32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2110-7MS32-0HL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.75 W
3VA2110-7MS32-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
3VA2110-7MS32-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2110-7MS32-0HL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2110-7MS32-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2110-7MS32-0HL0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

It's rated for a continuous current Iu of 100 A, and the temperature derating is tight: it holds the full 100 A from 40 °C up through 50 °C, then steps down to 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. That's a clean curve — you can push ambient to 50 °C without losing any ampacity, which matters in a crowded panel. The breaking capacity is the headline number here: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 52.5 kA at 690 V.

Release, auxiliaries, and what's inside the can

The overcurrent release is an ETU310M — that's an electronic trip unit with adjustable thermal and magnetic settings, typical for motor protection where you need to dial in the overload class and short-circuit pickup to match the motor full-load amps. The basic switch is order code 3VA2110-7MS32-0AA0, and the integrated auxiliary trip is 3VA9688-0BL30 — useful to know if you're replacing just the trip unit or the aux block separately. Mechanical endurance is rated at 20,000 operations. Power dissipation maxes out at 75 W.

Frequently asked questions

What type of trip unit does the 3VA2110-7MS32-0HL0 use?

It uses an ETU310M electronic overcurrent release, with adjustable thermal and magnetic settings suited for motor protection.

Does this breaker include a shunt trip?

Yes, it has a shunt trip (STL) design for remote tripping, plus an auxiliary contact block with 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch.

MPN