Siemens 3VA2110-7MS36-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2110-7MS36-0AB0 MCCB, 100 A, 3-Pole, 330

MPN3VA2110-7MS36-0AB0

Siemens SENTRON 3VA2110-7MS36-0AB0, molded case circuit breaker, 3-pole, 100 A continuous, interrupting capacity 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, 3.7 kA at 690 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-7MS36-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21107MS360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2110-7MS36-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.10 W

Protection & Trip Unit

3VA2110-7MS36-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2110-7MS36-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-7MS36-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2110-7MS36-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-7MS36-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2110-7MS36-0AB0 — 100 A MCCB for Starter Protection

The Siemens SENTRON 3VA2110-7MS36-0AB0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, designed specifically for starter protection in motor control centers and distribution panels. Its interrupting capacity reaches 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V — covering high-fault scenarios common in industrial power distribution. The breaker ships with two HP auxiliary switches integrated (design of auxiliary switch: 2 auxiliary switches HP), and the supplied basic switch carries order code 3VA21107MS360AA0.

Current Rating and Thermal Performance

The continuous current rating holds at 100 A across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to 70 °C, which simplifies panel thermal budgeting. Maximum power loss is 10 W, low enough that ventilation requirements are minimal for a breaker of this rating. Operating temperature range spans -25 °C to 70 °C; storage range is -40 °C to 80 °C, covering most indoor and conditioned outdoor installations.

Dimensions and Panel Fit

The breaker measures 181 mm high, 105 mm wide, and 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or direct-mount panel layouts without requiring extra enclosure depth.

MPN
3VA2110-7MS36-0AB0