Siemens 3VA2110-8KP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2110-8KP32-0AA0 SENTRON MCCB, 100 A, 3-Pole, 440

MPN3VA2110-8KP32-0AA0
Active

Siemens SENTRON 3VA2110-8KP32-0AA0, molded case circuit breaker, 3-pole, 100 A, ETU850 electronic trip unit, 440 kA at 240 V, IP40 front, communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2110-8KP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2110-8KP32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.7.7 W

Protection & Trip Unit

3VA2110-8KP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2110-8KP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2110-8KP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2110-8KP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2110-8KP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The Siemens 3VA2110-8KP32-0AA0 is a SENTRON molded case circuit breaker (MCCB) in the 3VA platform, rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to the top of the operating band. It carries a 3-pole design with an ETU850 electronic trip unit, meaning the protection curve is programmable and the breaker can communicate status over the integrated communication interface — no separate module required for basic connectivity. Breaking capacity reaches 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V — figures that put it squarely in high-fault-current distribution panels where SCCR headroom matters.

Panel fit and mounting

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep. Front face carries IP40 protection, so it is suitable for clean indoor panels; the enclosure behind the escutcheon must provide the overall IP rating for the assembly.

What the ratings mean for your panel

The 100 A rating is a flat line from 40 °C to 70 °C — no thermal derating curve to calculate for elevated ambient conditions inside a crowded enclosure. Maximum power loss is 7.7 W. Isolation voltage is rated at 800 V.