Siemens 3VA2116-0HM36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-0HM36-0AA0 SENTRON MCCB, 160 A, 3-Pole, ETU3

MPN3VA2116-0HM36-0AA0
Active

Siemens SENTRON 3VA series, Molded case circuit breaker, order code 3VA2116-0HM36-0AA0, 3-pole, 160 A, ETU330 electronic trip unit, 440 kA at 415 V, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2116-0HM36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2116-0HM36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.19.7 W
3VA2116-0HM36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L-conductor
3VA2116-0HM36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-0HM36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-0HM36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-0HM36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

160 A MCCB with ETU330 — selectivity and coordination for main feeders

The Siemens SENTRON 3VA2116-0HM36-0AA0 is a 3-pole molded case circuit breaker rated for 160 A continuous current across the full operating temperature range from 40 °C to 70 °C — no derating needed. That makes it a straight drop for a main feeder or large subfeed where you need the full ampacity at elevated panel ambient. It carries the ETU330 electronic trip unit with adjustable long-time pickup (I_g) from 32 A to 160 A and short-time/instantaneous pickup (I_i) up to 1,600 A. Panel integration: the 86 mm depth, 105 mm width, and 181 mm height fit standard SENTRON 3VA mounting footprints. Front IP40 protection covers the trip unit and nameplate; the breaker is rated for an isolation voltage of 800 V. Maximum power loss is 19.7 W.

An optional motor drive (product extension) is available for remote operation.

Temperature and environmental ratings

Operating ambient: -25 °C to 70 °C.

Trip unit and protection settings

The ETU330 electronic trip unit provides LSI protection (long-time, short-time, instantaneous). The adjustable long-time pickup range (32–160 A) lets you match cable ampacity without swapping the breaker frame. Short-time/instantaneous pickup adjustable up to 1,600 A. Ground-fault monitoring is available via summation current formation on the line conductor.

Frequently asked questions

Where can I buy 3VA2116-0HM36-0AA0 and how is it quoted?

It is available through independent distribution, quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2116-0HM36-0AA0 at 415 V?

440 kA at 415 V, and 187 kA at 690 V.

MPN
3VA2116-0HM36-0AA0