Siemens 3VA2116-5HL36-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HL36-0AC0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5HL36-0AC0

Siemens SENTRON 3VA2116-5HL36-0AC0, 3-pole molded case circuit breaker, 160 A rated current, 187 kA at 240 V, line protection design, 86 mm depth, 105 mm width, 181 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5HL36-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2116-5HL36-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5HL36-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5HL36-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HL36-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2116-5HL36-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HL36-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2116-5HL36-0AC0 is a 3-pole SENTRON molded case circuit breaker rated for 160 A continuous current at 40 °C through 70 °C — no derating needed across that band, which simplifies panel schedules in warm enclosures or near crusher drives. Its breaking capacity hits 187 kA at 240 V and still holds 121 kA at 415 V, so it handles high-fault industrial feeds without cascading upstream — built for the pit where fault currents run hot. At 690 V the SCCR drops to 3.7 kA, so if your line runs 690 V, verify the available fault current stays under that threshold.

Panel fit and wiring constraints

Dimensions are 86 mm deep, 105 mm wide, 181 mm tall. The auxiliary switch block is pre-configured as 2 HQ auxiliary switches — no field addition needed for status feedback to the PLC.

Frequently asked questions

Will 3VA2116-5HL36-0AC0 drop into a panel that was specified around 3VA2116-5HL32-0AK0 without rewiring?

Both are 3-pole SENTRON MCCBs with the same mounting footprint — same depth, width, and height — so a direct physical swap is possible, but verify the rated current and breaking capacity match your coordination study.

MPN