Skip to main content
Siemens 3VA2116-0HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

3VA2116-0HN32-0AA0 SENTRON MCCB, 160 A, 440 kA at 415 V

MPN3VA2116-0HN32-0AA0
Active

SENTRON 3VA2116-0HN32-0AA0, molded case circuit breaker, 3-pole, 160 A continuous, ETU350 release, 440 kA breaking capacity at 415 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2116-0HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2116-0HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.19.7 W
3VA2116-0HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-0HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-0HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-0HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-0HN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The SENTRON 3VA2116-0HN32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, designed to bolt into a panel and handle 160 A continuous current without derating from 40 °C up to 70 °C.

That's rare: most MCCBs start pulling current back above 40 °C. If your panel runs hot, this breaker keeps its full 160 A. Insulation voltage rated at 800 V, operating voltage at 690 V AC. Max power loss is 19.7 W per breaker.

Physical footprint & panel integration

Bolts into a standard MCCB cutout — no DIN rail on this class; it's screw-mounted. Three-pole, so it occupies one full slot in a multi-breaker lineup. Leave 25 mm minimum side clearance between units for heat dissipation and busbar access.

Compliance & approvals

Reference code per IEC 81346-2: Q. The brand provides RoHS, REACH, UL, and IEC compliance documentation — standard for SENTRON series. No specific cert codes in this listing, but the product design falls under IEC 60947-2 for MCCBs.

Frequently asked questions

Will 3VA2116-0HN32-0AA0 drop into a panel specified around 3VA2116-5JP32-0AE0?

Both are 3-pole SENTRON 3VA frame size breakers with the same 160 A continuous rating and the same physical footprint (181 x 105 x 86 mm). The 5JP32 variant carries a different trip unit and optional accessories; the 0HN32 drops into the same panel cutout without rewiring, but verify the trip curve and aux contact configuration against your coordination study.

What is the listed depth of 3VA2116-0HN32-0AA0?

86 mm (3.39 in).

What is the listed width of 3VA2116-0HN32-0AA0?

105 mm (4.13 in).

MPN
3VA2116-0HN32-0AA0