Skip to main content
Siemens 3VA2116-0KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-0KQ42-0AA0 SENTRON MCCB, 160 A, ETU860, 4-Po

MPN3VA2116-0KQ42-0AA0
Active

Siemens SENTRON 3VA2116-0KQ42-0AA0, molded case circuit breaker, 4-pole, 160 A continuous, ETU860 electronic trip unit, 440 kA at 415 V, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2116-0KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2116-0KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.19.7 W
3VA2116-0KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes
3VA2116-0KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-0KQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-0KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-0KQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

SENTRON 3VA2116-0KQ42-0AA0 — 160 A MCCB with ETU860 Electronic Trip

Its ETU860 electronic trip unit provides adjustable overload protection from 240 A up to 1 600 A, with a fixed full-scale value of 160 A — meaning the trip curve is set for the breaker's frame, not the load.

Trip Unit and Protection Configuration

The ETU860 electronic trip unit supports ground-fault monitoring via summation current formation on the L + N conductor — a common requirement for TN-S or TT systems where you need residual current detection without a separate RCD. The N-conductor protection is adjustable from OFF to 20%–100% of the phase rating, giving flexibility for systems where the neutral is undersized or needs to be switched off. No undervoltage release or voltage trip is fitted as standard — those would be add-on accessories.

Thermal Performance and Environmental Range

That is unusual for a molded case breaker; most start derating above 40 °C. The maximum power loss is 19.7 W, which is moderate for a 160 A frame and manageable in a ventilated enclosure. The IP40 front protection means it is suited for indoor panel mounting, not washdown environments.

As a Siemens SENTRON product, the 3VA2116-0KQ42-0AA0 carries the usual compliance documentation for industrial MCCBs: CE marking for the European market, UL/CSA listing for North America, and RoHS/REACH declarations. Specific certificate numbers should be verified against the project's local code requirements.

Frequently asked questions

What is the breaking capacity of 3VA2116-0KQ42-0AA0 at 415 V and 690 V?

The breaking capacity is 440 kA at 415 V and 187 kA at 690 V, giving substantial fault-current headroom for industrial mains or sub-distribution.

What trip unit does this MCCB use?

It uses the ETU860 electronic trip unit with adjustable overload protection from 240 A to 1 600 A, ground-fault monitoring via summation current, and adjustable N-conductor protection (OFF, 20%–100%).

Where can I buy 3VA2116-0KQ42-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 3VA2116-0KQ42-0AA0 drop into a panel specified around 3VA2116-5HM42-0CC0?

Both are 4-pole SENTRON 3VA frame breakers with the same 86 mm depth and 140 mm width, so the physical footprint is identical. The key difference is the trip unit — this one uses ETU860, while the other uses a different electronic trip. Verify the trip curve and protection settings match your coordination study before swapping.

MPN
3VA2116-0KQ42-0AA0