Skip to main content
Siemens 3VA2116-0KQ36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-0KQ36-0AA0 SENTRON MCCB, 160 A, 440 kA at 41

MPN3VA2116-0KQ36-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2116-0KQ36-0AA0, 3-pole, 160 A continuous, 440 kA breaking capacity at 415 V, ETU860 electronic trip unit, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2116-0KQ36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2116-0KQ36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.19.7 W
3VA2116-0KQ36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2116-0KQ36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-0KQ36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-0KQ36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-0KQ36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The N-conductor protection is adjustable from OFF to 20%–160% of the phase setting, giving flexibility for 4-pole applications where the neutral needs its own overload curve. Communication function is onboard, so it can talk to a BMS or SCADA via the SENTRON bus system.

Panel integration and physical fit

Dimensions are 105 mm wide, 181 mm high, 86 mm deep — a standard 3-pole MCCB footprint for the 3VA2 frame. No special cutout or adapter required for a standard Siemens MCCB mounting base.

Frequently asked questions

Where can I buy 3VA2116-0KQ36-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2116-0KQ36-0AA0?

The breaking capacity is 440 kA at 415 V and 187 kA at 690 V, making it suitable for high-fault-current main breakers.

Does 3VA2116-0KQ36-0AA0 have communication capability?

Yes, the circuit breaker includes a communication function for integration with a BMS or SCADA system via the SENTRON bus.

MPN
3VA2116-0KQ36-0AA0