Skip to main content
Siemens 3VA2116-5HL32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HL32-0AH0 SENTRON MCCB, 160 A, 3-Pole, Line

MPN3VA2116-5HL32-0AH0

Siemens SENTRON 3VA2116-5HL32-0AH0, Molded case circuit breaker, 3-pole, 160 A, line protection, 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5HL32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2116-5HL32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5HL32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5HL32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HL32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2116-5HL32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HL32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2116-5HL32-0AH0 — 160 A MCCB, Line Protection Duty

It carries a 187 kA breaking capacity at 240 V, stepping down to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — so the interrupting capability drops sharply above 500 V, which matters when you're coordinating with upstream gear on a 690 V bus.

Fit and Mounting — Panel Integration

The 3-pole format with line-protection trip curve is the common choice for feeder and main breaker positions in 160 A rated panels.

Auxiliary Switching and Indication

The trip indicator is present on the front face — useful for a quick visual check on the panel door without opening it.

Frequently asked questions

What are the key ratings for 3VA2116-5HL32-0AH0?

Continuous current 160 A, 3-pole, breaking capacity 187 kA at 240 V, 121 kA at 415 V/440 V, 75.6 kA at 500 V, 3.7 kA at 690 V. Insulation voltage 800 V. Maximum power loss 25.5 W.

Where can I buy 3VA2116-5HL32-0AH0?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

Will 3VA2116-5HL32-0AH0 drop into a panel specified for 3VA2116-5HL32-0AK0?

Both are 3-pole SENTRON 3VA breakers with the same 105 x 181 x 86 mm footprint and 160 A frame, so the mechanical fit is identical. The difference is in the trip unit or internal accessories — verify the trip curve and auxiliary configuration before substituting.

MPN
3VA2116-5HL32-0AH0