Skip to main content
Siemens 3VA2116-5HL32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HL32-0BH0 SENTRON MCCB, 160 A, 187 kA

MPN3VA2116-5HL32-0BH0

Siemens SENTRON, Molded case circuit breaker, 3VA2116-5HL32-0BH0, 3-pole, 160 A, 187 kA at 240 V, ETU320 release, undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5HL32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2116-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2116-5HL32-0BH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C154 A
Current at 60 °C148 A
Current at 65 °C142 A
Current at 70 °C136 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.28 W
3VA2116-5HL32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2116-5HL32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HL32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2116-5HL32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HL32-0BH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

MCCB with real interrupting muscle

It packs a 187 kA interrupting capacity at 240 V, dropping to 121 kA at 415 V and 440 V, then 79 kA at 500 V, and 4.25 kA at 690 V — that's real fault-clearing power for high-available-current plant feeders or transformer secondaries. Power loss tops out at 28 W, so heat management in a packed panel is manageable.

The 86 mm depth means it clears shallow enclosures where deeper breakers won't fit. It ships with a basic switch (3VA2116-5HL32-0AA0) and an integrated auxiliary trip (3VA9608-0BB11) for remote status and shunt-trip capability.

The thermal derating curve is flat from 40 °C to 50 °C at 160 A, then steps down: 154 A at 55 °C, 148 A at 60 °C, 142 A at 65 °C, and 136 A at 70 °C. Latching endurance is 20,000 operations.

Frequently asked questions

Where can I buy 3VA2116-5HL32-0BH0 and how is it quoted?

It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest functional second-source to 3VA2116-5HL32-0BH0?

The 3VA2116-5HL32-0AK0 is a close functional peer — same frame and current rating but with a different trip unit or release configuration. Panel fit and dimensions are identical, so it drops in without rewiring, but verify the protection curve matches your coordination study.

MPN
3VA2116-5HL32-0BH0