Siemens 3VA2116-5HL32-0DE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HL32-0DE0 3VA2 IEC Frame 160 MCCB, 55kA @ 4

MPN3VA2116-5HL32-0DE0

Siemens 3VA2 IEC frame 160 MCCB, breaking capacity class M, Icu=55kA @ 415V, 3-pole, line protection ETU320 LI, In=160A, overload Ir=63-160A, short-circuit Ii=1.5-10xIn, with undervoltage release 208-230V AC 50/60Hz and 4 auxiliary switch changeover.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2116-5HL32-0DE0 is a 3-pole IEC frame 160 molded-case circuit breaker with breaking capacity class M — Icu=55kA at 415V AC — fitted with an ETU320 LI trip unit. Rated In=160A, the overload protection Ir is adjustable from 63A to 160A, and the instantaneous short-circuit pickup Ii ranges 1.5 to 10 times In. The unit ships with an undervoltage release (208-230V AC 50/60Hz) and four auxiliary switch changeover contacts pre-installed.

The ETU320 LI trip unit provides adjustable long-time (overload) and instantaneous (short-circuit) protection only; no short-time delay, so it's a straight line-protection device for feeders or large branch circuits where selective coordination with downstream breakers isn't required. The 160A frame with Ir down to 63A means you can size the overload protection to the cable or load without swapping the breaker body.

The 3VA2 frame uses the same cutout and busbar pattern as other 160A-frame Siemens breakers, so retrofitting into an existing 3VA lineup is straightforward — no re-drilling of the backplate or re-termination of busbars needed. The undervoltage release and auxiliary switches are factory-fitted; verify control voltage polarity at the release terminals before energizing.

Frequently asked questions

Where can I buy the 3VA2116-5HL32-0DE0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of the 3VA2116-5HL32-0DE0?

It is a 3-pole IEC frame 160 MCCB with breaking capacity class M: Icu=55kA at 415V AC. The ETU320 LI trip unit provides overload protection adjustable from 63A to 160A and instantaneous short-circuit protection adjustable from 1.5 to 10 times In (In=160A).

What compliance documentation is available for this breaker?

As a current-production Siemens 3VA series breaker, it carries IEC 60947-2 certification. RoHS and REACH declarations are standard from the manufacturer; specific documents can be requested at quote time.

MPN