3VA2116-5HL32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2116-5HL32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5HL32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5HL32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HL32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2116-5HL32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HL32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2116-5HL32-0HC0 — 160 A MCCB with High Interrupting Capacity

It carries a continuous current rating of 160 A across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel layout when the breaker sits near other heat sources. Breaking capacity is the headline number here: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

Dimensions are 105 mm wide, 181 mm tall, 86 mm deep — a standard 3-pole MCCB footprint. Power loss is 25.5 W maximum at rated load — relevant for thermal calculations inside a sealed panel. Operating temperature range is -25 °C to 70 °C; storage from -40 °C to 80 °C.

Frequently asked questions

Will 3VA2116-5HL32-0HC0 drop into a panel specified for 3VA2116-5HL32-0AK0?

Both are 3-pole SENTRON MCCBs in the same physical footprint (105 mm wide, 181 mm tall, 86 mm deep), so the panel cutout and mounting pattern are identical. The difference is in the internal accessories — verify the shunt trip and auxiliary switch configuration match your schematic before swapping.