Skip to main content
Siemens 3VA2116-5HL32-0HL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HL32-0HL0 SENTRON MCCB, 160 A, 3-Pole

MPN3VA2116-5HL32-0HL0

Siemens SENTRON 3VA2116-5HL32-0HL0, molded case circuit breaker, 160 A continuous, 3-pole, 187 kA at 240 V breaking capacity, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5HL32-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2116-5HL32-0HL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5HL32-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5HL32-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HL32-0HL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2116-5HL32-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HL32-0HL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2116-5HL32-0HL0 — 160 A MCCB, Line Protection

The Siemens SENTRON 3VA2116-5HL32-0HL0 is a 3-pole molded case circuit breaker rated for 160 A continuous current at 40 °C through 70 °C ambient — no derating needed across that full operating range. Breaking capacity runs 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 690 V figure confirms this is a 3-pole breaker on a 4-wire system where the fourth pole is switched but not protected. Dimensions are 105 mm wide × 181 mm high × 86 mm deep — standard SENTRON 3VA2 frame size, so it drops into existing 3VA2 panel cutouts and busbar arrangements without rework.

Frequently asked questions

Does the 3VA2116-5HL32-0HL0 include a shunt trip?

Yes, it is equipped with a shunt trip release (STL) for remote tripping, plus a 2+1+1 auxiliary switch configuration.

MPN
3VA2116-5HL32-0HL0