Skip to main content
Siemens 3VA2116-5HL36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HL36-0HC0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5HL36-0HC0

Siemens SENTRON 3VA2116-5HL36-0HC0, molded case circuit breaker, 3-pole, 160 A continuous rating, breaking capacity 187 kA at 240 VAC, 121 kA at 415/440 VAC, 86 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5HL36-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2116-5HL36-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5HL36-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5HL36-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HL36-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2116-5HL36-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HL36-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The 3-pole design with shunt trip (STL) and two auxiliary switches (HQ) makes it suitable for remote tripping and status feedback in motor control centers or main feeder applications.

This MCCB delivers 187 kA at 240 VAC, 121 kA at 415 V and 440 VAC, 75.6 kA at 500 VAC, and 3.7 kA at 690 VAC. The steep drop above 500 V reflects the arc extinction limits of the 160 A frame; at 690 V the part is still usable but only where fault current stays under 3.7 kA. For a 415 V distribution board fed by a typical 1 MVA transformer (prospective fault around 35–50 kA), the 121 kA rating gives comfortable margin without cascading upstream.

Footprint is 105 mm wide × 181 mm high × 86 mm deep — a standard 3-pole MCCB envelope that drops into existing SENTRON 3VA mounting bases. The 86 mm depth (3.39 in) leaves room for rear-access busbars in shallow enclosures. Shunt trip (STL) and two auxiliary switches (HQ) are factory-integrated; no field-add kit needed. Maximum power loss is 25.5 W at rated load — account for that in enclosed panel heat rise calculations.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V?

121 kA at 415 VAC, which also applies at 440 VAC.

Does this breaker include a shunt trip and auxiliary switches?

Yes, it comes with a factory-integrated shunt trip (STL) and two auxiliary switches (HQ).

Where can I buy the 3VA2116-5HL36-0HC0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN