Skip to main content
Siemens 3VA2116-5HL36-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HL36-0KA0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5HL36-0KA0

Siemens SENTRON 3VA2116-5HL36-0KA0, molded case circuit breaker, 3-pole, 160 A rated continuous current, 187 kA interrupting at 240 V, line protection with shunt trip release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5HL36-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HL360AA0
3VA2116-5HL36-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5HL36-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5HL36-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HL36-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-5HL36-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HL36-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2116-5HL36-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous current at 40 °C, designed for line protection in distribution panels. Its interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — meaning it can safely clear faults across a wide voltage range without cascading upstream. The 800 V rated insulation voltage gives headroom for 480 V or 600 V class systems. A shunt trip release (STL) is built in for remote tripping, useful in emergency-stop or load-shedding circuits.

The breaker measures 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that mounts on a DIN rail or panel-mount base in a distribution enclosure. The 105 mm width matches the typical 3-pole slot in a SENTRON panelboard.

Thermal performance and derating

The 160 A continuous rating holds flat from 40 °C through 70 °C ambient — no derating needed up to that ceiling. Maximum power loss is 25.5 W at rated load.

Frequently asked questions

Where can I buy 3VA2116-5HL36-0KA0 and how do I get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is 3VA2116-5HL36-0KA0's listed depth?

The depth is 86 mm (3.39 in).

What is 3VA2116-5HL36-0KA0's listed width?

The width is 105 mm (4.13 in).

Will 3VA2116-5HL36-0KA0 drop into a panel specified around 3VA2116-5HL32-0AK0 without rewiring?

The 3VA2116-5HL32-0AK0 is a different variant with different ratings; physical dimensions (105 mm width, 181 mm height, 86 mm depth) are the same for the 3VA2 frame, so it will fit the same mounting footprint and bus connections. However, verify the trip unit settings and shunt trip wiring differ between the two order codes.

What compliance documentation does Siemens provide for 3VA2116-5HL36-0KA0?

Siemens SENTRON MCCBs carry IEC 60947-2 certification and are typically UL 489 listed. RoHS and REACH declarations are available from Siemens documentation. Specific certificates should be confirmed against the exact order code at time of order.

MPN
3VA2116-5HL36-0KA0