Specifications

3VA2116-5HL36-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HL360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2116-5HL36-0KC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5HL36-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5HL36-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HL36-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2116-5HL36-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HL36-0KC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Its 3-pole design and line-protection characteristic make it a straight choice for feeder or main breaker duty in a distribution panel where you need a single interrupting device that holds its rating in a warm enclosure.

This MCCB delivers 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

Integrated accessories

No undervoltage release, no ground-fault module, no communication function — this is a clean line-protection breaker with the most common add-ons already built in. The shunt trip lets a safety circuit or emergency-stop button open the breaker remotely without needing a separate contactor.

Frequently asked questions

What is the breaking capacity of 3VA2116-5HL36-0KC0 at 415 V?

121 kA at 415 V AC.

What accessories are included on this MCCB?

A shunt trip (STL) for remote tripping and two auxiliary switches (HQ) for status indication. No undervoltage release, ground-fault module, or communication function.

Where can I buy 3VA2116-5HL36-0KC0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2116-5HL36-0KC0