Siemens 3VA2116-5HL46-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2116-5HL46-0HC0 MCCB, 160 A, 187 kA at 24

MPN3VA2116-5HL46-0HC0

Siemens SENTRON 3VA2116-5HL46-0HC0, molded case circuit breaker, 4-pole, 160 A, ETU320 electronic trip unit, shunt trip, 187 kA at 240 V, 121 kA at 415 V, 3.75 kA at 690 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5HL46-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2116-5HL46-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2116-5HL46-0HC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C154 A
Current at 60 °C148 A
Current at 65 °C142 A
Current at 70 °C136 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V3.75 kA
Power loss, max.26 W

Protection & Trip Unit

3VA2116-5HL46-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320

Construction & Connection

3VA2116-5HL46-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5HL46-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2116-5HL46-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5HL46-0HC0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth107 mm

Product details

MCCB for line protection with ETU320 and shunt trip

The Siemens SENTRON 3VA2116-5HL46-0HC0 is a 4-pole molded case circuit breaker (MCCB) rated for 160 A continuous current, fitted with an ETU320 electronic trip unit for line protection. It carries a shunt trip (STL) release and two auxiliary switches (HQ version) for remote status feedback. Breaking capacity runs 187 kA at 240 V AC, 121 kA at 415 V AC, and 3.75 kA at 690 V AC — the 690 V figure is the one to watch if you're protecting a 690 V motor feeder; at that voltage the interrupting rating drops sharply, so verify the available fault current at the panel.

Thermal derating and panel fit

The 160 A rating holds up to 50 °C ambient; above that it derates linearly to 136 A at 70 °C. That matters if this breaker sits in a crowded enclosure near drives or transformers — at 65 °C you're down to 142 A, so size the load accordingly. Dimensions are 140 mm wide, 181 mm tall, 107 mm deep — it's a standard SENTRON 3VA frame size, so it slots into existing panel layouts without re-drilling the mounting plate. Front IP40 keeps out tools and fingers but not washdown; keep it behind a sealed door in wet environments.

Frequently asked questions

Does the 3VA2116-5HL46-0HC0 have a shunt trip?

Yes, it includes an integrated shunt trip (STL) release for remote tripping via a control signal. The auxiliary trip order code is 3VA9688-0BL30.

What trip unit does the 3VA2116-5HL46-0HC0 use?

It uses the ETU320 electronic trip unit for line protection. This is a basic unit without communication, phase-failure detection, or ground-fault monitoring.

What is the closest functional second-source to the 3VA2116-5HL46-0HC0?

The 3VA1010-2ED32-0JA0 is a smaller-frame SENTRON MCCB but with different ratings and footprint — it won't drop into a panel wired for the 3VA2 frame without rewiring. For a true functional match in the same frame, stick with the 3VA2 series and match the 160 A rating and ETU320 trip unit.

MPN