Siemens 3VA2116-5HN32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HN32-0AB0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5HN32-0AB0

Siemens SENTRON 3VA2116-5HN32-0AB0, molded case circuit breaker, 3-pole, 160 A, line protection design, 187 kA interrupting at 240 V, 86 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5HN32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2116-5HN32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5HN32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-5HN32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5HN32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2116-5HN32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5HN32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

160 A MCCB for line protection — interrupting capacity across voltage levels

The Siemens 3VA2116-5HN32-0AB0 is a SENTRON molded case circuit breaker (MCCB) rated for 160 A continuous at 40 °C through 70 °C — no derating needed across that span, which simplifies panel sizing in warm enclosures. Three poles, line protection design, no ground-fault monitoring, no undervoltage release, no communication module. It carries two built-in auxiliary switches (HP type) for status feedback to a PLC or indicator lamp. Interrupting capacity is the headline: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. That 187 kA at 240 V covers high-fault service-entrance or transformer-secondary applications where available fault current is severe. The 121 kA at 415 V handles most industrial distribution panels in 400 V class systems. At 690 V the 3.7 kA figure is low — this breaker is not a primary choice for 690 V circuits unless the fault current is well below that threshold.

Panel fit — dimensions and mounting

Dimensions: 105 mm wide, 181 mm high, 86 mm deep. That 105 mm width is roughly 4.13 inches — standard for a 3-pole MCCB in this frame size. Mounts on a DIN rail or direct-panel via the screw terminals. The 86 mm depth (3.39 in) leaves clearance behind a standard 200 mm deep enclosure door. Operating temperature range -25 °C to 70 °C; storage from -40 °C to 80 °C. Rated insulation voltage 800 V.

Frequently asked questions

Where can I buy 3VA2116-5HN32-0AB0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time.

What is the interrupting capacity of 3VA2116-5HN32-0AB0 at 415 V?

At 415 V the interrupting capacity is 121 kA. At 240 V it is 187 kA, at 440 V also 121 kA, at 500 V it drops to 75.6 kA, and at 690 V to 3.7 kA.

Does 3VA2116-5HN32-0AB0 include ground-fault monitoring or undervoltage release?

No. This variant has no ground-fault monitoring and no undervoltage release. It is a line-protection-only breaker with two built-in auxiliary switches (HP type).

MPN