Skip to main content
Siemens 3VA2116-5HN32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HN32-0AH0 Sentron MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5HN32-0AH0

Siemens SENTRON 3VA2116-5HN32-0AH0, 3-pole molded case circuit breaker, 160 A continuous, 187 kA interrupting at 240 V AC, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5HN32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2116-5HN32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5HN32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5HN32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5HN32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2116-5HN32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5HN32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2116-5HN32-0AH0 — 160 A MCCB, 3-Pole, 187 kA IC

The Siemens SENTRON 3VA2116-5HN32-0AH0 is a 3-pole molded case circuit breaker rated for 160 A continuous current at 40 °C through 70 °C — no derating needed across that full ambient span, which simplifies panel design in warm enclosures. Interrupting capacity reaches 187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and 3.7 kA at 690 V. It's a straight thermal-magnetic or electronic-trip MCCB for feeder or main service.

Mounting & panel fit

The width of 105 mm is the 3-pole frame footprint; verify busbar or lug spacing against the panel layout. Maximum power loss is 25.5 W at rated current.

That's a fixed assembly — you're not adding a field-installable accessory block. The supplied basic switch order code is 3VA21165HN320AA0, which confirms the internal mechanism variant.

Frequently asked questions

What is the interrupting capacity of 3VA2116-5HN32-0AH0 at different voltages?

The breaker delivers 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

How do I get current pricing and availability for 3VA2116-5HN32-0AH0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What are the physical dimensions of this breaker?

The 3VA2116-5HN32-0AH0 measures 105 mm wide, 181 mm tall, and 86 mm deep.

Does this breaker include auxiliary or alarm contacts?

Yes, it comes factory-fitted with 2 auxiliary switches plus 1 trip alarm switch (HQ type). No field-installable accessory block is needed.

MPN