3VA2116-5HN32-0JH0 SENTRON MCCB, 160 A, 3-Pole, 121 kA at 41

MPN3VA2116-5HN32-0JH0

Siemens SENTRON 3VA2116-5HN32-0JH0, molded case circuit breaker, 3-pole, 160 A continuous, 121 kA breaking capacity at 415 V, line protection design with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5HN32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2116-5HN32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5HN32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-5HN32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5HN32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2116-5HN32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5HN32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what the ratings mean

The Siemens SENTRON 3VA2116-5HN32-0JH0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Its interrupting capacity hits 121 kA at 415 V, which means it can safely clear a fault at that level without upstream devices needing to trip, a key figure for high-fault panels in industrial distribution.

Breaking capacity across voltages

This MCCB delivers 187 kA at 240 V, 121 kA at both 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The steep drop at 690 V is typical for a 160 A frame — the arc extinction limits at higher voltage. For 690 V applications, confirm the available fault current stays under 3.7 kA.

Built-in accessories and fit

Factory-fitted with a shunt trip (STL), two auxiliary switches, and one trip alarm switch (HQ). The shunt trip lets you remotely open the breaker via a control signal — useful for emergency-off or interlock circuits. No undervoltage release or ground-fault monitoring on this variant. Dimensions: 105 mm wide, 181 mm tall, 86 mm deep. The 86 mm depth is the projection into the panel; verify clearance against your enclosure depth, especially with rear-mounted busbars.

Frequently asked questions

Where can I buy 3VA2116-5HN32-0JH0 and how do I get a price?

This part is sourced to order through independent distribution. Submit an RFQ; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2116-5HN32-0JH0 at 415 V?

121 kA at 415 V. It also delivers 187 kA at 240 V and 75.6 kA at 500 V.

What accessories come fitted on this MCCB?

Factory-installed: a shunt trip (STL), two auxiliary switches, and one trip alarm switch (HQ). No undervoltage release or ground-fault monitoring.

Does 3VA2116-5HN32-0JH0 require derating at high ambient temperatures?

No derating needed up to 70 °C — the 160 A rating holds from 40 °C through 70 °C.