Skip to main content
Siemens 3VA2116-5HN32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HN32-0KL0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5HN32-0KL0

Siemens SENTRON 3VA2116-5HN32-0KL0, molded case circuit breaker, 3-pole, 160 A continuous, 187 kA breaking capacity at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5HN32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2116-5HN32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5HN32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-5HN32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5HN32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2116-5HN32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5HN32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What the ratings mean for fit

The 3VA2116-5HN32-0KL0 is a 3-pole SENTRON molded case circuit breaker rated 160 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to that ceiling. Its interrupting capacity hits 187 kA at 240 V and 121 kA at 415 V, which means it can clear fault currents at those levels without upstream cascading, critical for high-fault panels behind a large transformer. The 75.6 kA at 500 V and 3.7 kA at 690 V cover the upper voltage bands where arc energy is higher. A shunt trip (STL) auxiliary release is built in for remote emergency-off, and the auxiliary switch complement (2 aux + 1 trip alarm + 1 electrical alarm HQ) gives the PLC or safety relay the status feedback it needs.

Panel fit and mounting

Dimensions: 105 mm wide, 181 mm high, 86 mm deep. Mounts on a DIN rail or directly to a backplate via the screw terminals. The 3-pole footprint is standard for a 160 A MCCB; check the depth clearance for the shunt trip wiring and auxiliary cable bundle — the 86 mm depth is from the mounting surface to the front of the breaker body, not including the handle throw.

Frequently asked questions

Where can I buy the 3VA2116-5HN32-0KL0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of the 3VA2116-5HN32-0KL0?

187 kA at 240 V, 121 kA at 415 V, 121 kA at 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

What auxiliary switches and releases does this MCCB include?

It includes 2 auxiliary switches, 1 trip alarm switch, 1 electrical alarm switch (HQ), and a shunt trip (STL) release.

MPN
3VA2116-5HN32-0KL0