Skip to main content
Siemens 3VA2116-5HN36-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HN36-0AG0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5HN36-0AG0

Siemens SENTRON 3VA2116-5HN36-0AG0, molded case circuit breaker, 3-pole, 160 A rated continuous current, 187 kA interrupting capacity at 240 V AC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5HN36-0AG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11

Ratings

3VA2116-5HN36-0AG0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5HN36-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-5HN36-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5HN36-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2116-5HN36-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5HN36-0AG0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

160 A MCCB with flat thermal response to 70 °C

The Siemens SENTRON 3VA2116-5HN36-0AG0 is a 3-pole molded case circuit breaker rated 160 A continuous current, with a rated insulation voltage of 800 V. It holds its full 160 A rating across the entire ambient range from 40 °C to 70 °C — no derating curve to chase when the panel runs hot. Interrupting capacity runs 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V, so it handles high-fault service entrance or distribution positions where the available fault current is substantial.

Panel fit and integration

Dimensions are 181 mm high, 105 mm wide, 86 mm deep — standard MCCB footprint for a 160 A frame. The supplied basic switch is 3VA21165HN360AA0, and the auxiliary switch configuration is one auxiliary switch plus one trip alarm switch (HP type). No undervoltage release, no ground-fault monitoring, no communication function on this variant — it's a straight line-protection breaker. Maximum power loss is 25.5 W, so account for that in enclosed panel thermal calculations.

Frequently asked questions

What are the key ratings for 3VA2116-5HN36-0AG0?

It is a 3-pole MCCB rated 160 A continuous current with an 800 V rated insulation voltage. Interrupting capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The full 160 A rating holds from 40 °C to 70 °C ambient.

Where can I buy 3VA2116-5HN36-0AG0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ with your target quantity and delivery window; availability and current pricing are confirmed at quote time.

MPN
3VA2116-5HN36-0AG0