Skip to main content
Siemens 3VA2116-5HN36-0CL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HN36-0CL0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5HN36-0CL0

Siemens SENTRON 3VA2116-5HN36-0CL0, molded case circuit breaker, 3-pole, 160 A continuous, 187 kA interrupting at 240 V, line protection design, undervoltage release, 86 x 105 x 181 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5HN36-0CL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2116-5HN36-0CL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.28 W

Protection & Trip Unit

3VA2116-5HN36-0CL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-5HN36-0CL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5HN36-0CL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2116-5HN36-0CL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5HN36-0CL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for high-fault line protection

The Siemens SENTRON 3VA2116-5HN36-0CL0 is a 3-pole molded case circuit breaker rated for 160 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed in a warm cabinet. It is designed for line protection, meaning it sits at the feeder or main distribution point rather than protecting a specific motor or load. The interrupting capacity hits 187 kA at 240 V AC and 121 kA at 415 V / 440 V, so it handles high-fault conditions in industrial switchboards without cascading upstream. The 86 mm depth and 105 mm width fit standard panel cutouts for this frame class.

Built-in undervoltage release and auxiliary switch complement

This MCCB ships with an undervoltage release (UVR) that trips the breaker when supply voltage drops below a threshold — common in safety circuits where a loss of control power must open the main disconnect. The auxiliary switch complement includes two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ type), giving the panel builder four separate signal paths for status feedback to the PLC or annunciator. No communication function is built in; this is a hardwired breaker.

Frequently asked questions

Does 3VA2116-5HN36-0CL0 include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) as the auxiliary release type.

MPN
3VA2116-5HN36-0CL0