Siemens 3VA2116-5HN36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HN36-0HC0 IEC MCCB, 160A, 55kA @ 415V

MPN3VA2116-5HN36-0HC0

Siemens 3VA2 IEC frame 160 MCCB, breaking capacity class M, Icu=55kA @ 415V AC, 3-pole, ETU350 LSI electronic trip unit, In=160A, shunt trip + 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2116-5HN36-0HC0 is a 3VA2 IEC frame 160 molded case circuit breaker with a 55 kA interrupting capacity at 415 V AC — class M breaking capacity per IEC 60947-2. That rating means it clears fault currents up to 55 kA without external fuses or current-limiting reactors, which simplifies panel coordination in industrial distribution boards where the available fault current sits in that range. The ETU350 electronic trip unit provides LSI protection: long-time (Ir adjustable 63 A to 160 A), short-time (Isd 1.5 to 10 x Ir), and instantaneous (Ii fixed at 10 x In). The adjustable short-time band lets you achieve selective coordination downstream — a key requirement for main or feeder breakers in a tiered distribution scheme. This variant includes a shunt trip (STL) rated 12–30 V DC / 24 V AC 50/60 Hz and two auxiliary switches (HQ). All connections are clamp-type, which speeds panel wiring and reduces torque-verification steps compared to traditional screw terminals.

For a BOM-critical line item, the current lifecycle status removes the urgency of a last-time-buy window.

The clamp-type terminals accept copper or aluminum conductors within the rated cross-section range per the installation manual — verify lug sizing against your cable before terminating. The shunt trip coil draws power from a separate 12–30 V DC or 24 V AC supply; it is not self-powered from the breaker's line side. Ensure the control transformer or DC supply is rated for the inrush of the shunt trip coil, typically several times the holding current for 50–100 ms. Two auxiliary switches (HQ) provide normally-open and normally-closed contacts for status monitoring. They are factory-fitted and share the same terminal numbering as the standard 3VA2 aux block — no additional wiring harness needed.

Frequently asked questions

What is the breaking capacity of 3VA2116-5HN36-0HC0?

The interrupting capacity is Icu = 55 kA at 415 V AC, class M per IEC 60947-2.

What trip unit and protection settings does this breaker have?

It uses an ETU350 electronic trip unit with LSI protection: Ir adjustable 63–160 A, Isd adjustable 1.5–10 x Ir, and Ii fixed at 10 x In.

What accessories are included on this variant?

This variant includes a shunt trip (STL) rated 12–30 V DC / 24 V AC and two auxiliary switches (HQ).

Where can I buy 3VA2116-5HN36-0HC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.