Skip to main content
Siemens 3VA2116-5HN36-0HH0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2116-5HN36-0HH0 MCCB, 160 A, 3-Pole, 187 kA at 24

MPN3VA2116-5HN36-0HH0

SENTRON 3VA2116-5HN36-0HH0, molded case circuit breaker, 3-pole, 160 A continuous, interrupting 187 kA at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5HN36-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2116-5HN36-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5HN36-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-5HN36-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5HN36-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2116-5HN36-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5HN36-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The SENTRON 3VA2116-5HN36-0HH0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous current, designed for line protection in distribution panels and industrial switchgear. Its interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — covering most low-voltage fault scenarios without needing an upstream current-limiting fuse. The 160 A rating holds across the full ambient temperature range from 40 °C to 70 °C, so no derating is needed for warm enclosures.

Panel fit and integration

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard MCCB footprint that fits most DIN-rail or panel-mount enclosures without re-drilling. The breaker ships with a shunt trip (STL) release and an auxiliary switch block configurable as 2 auxiliary switches plus 1 trip alarm switch (HQ), covering remote trip and status feedback. A voltage-trigger indicator and trip indicator are built in, giving local visual status without needing extra pilot lights.

MPN
3VA2116-5HN36-0HH0