Skip to main content
Siemens 3VA2116-5HN36-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5HN36-0KC0 SENTRON MCCB, 160 A, 187 kA

MPN3VA2116-5HN36-0KC0

Siemens SENTRON 3VA2116-5HN36-0KC0, 3-pole molded case circuit breaker, 160 A rated continuous current, 187 kA breaking capacity at 240 V, ETU350 electronic trip unit, shunt trip release, 2 HQ auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5HN36-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2116-5HN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2116-5HN36-0KC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C154 A
Current at 60 °C148 A
Current at 65 °C142 A
Current at 70 °C136 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5HN36-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350

Construction & Connection

3VA2116-5HN36-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5HN36-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2116-5HN36-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5HN36-0KC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What it is and what it does

The Siemens SENTRON 3VA2116-5HN36-0KC0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying 160 A continuous current (Iu) across a 40–50 °C ambient window before derating begins at 55 °C. The ETU350 electronic trip unit handles the overcurrent release curve; a separate shunt trip (STL) provides remote tripping capability via the auxiliary release circuit. Two HQ auxiliary switches are integrated for status feedback to the PLC or panel indication. Breaking capacity runs 187 kA at 240 V, 121 kA at 415/440 V, 79 kA at 500 V, and 4.25 kA at 690 V — figures that place it in the high-interrupting range for industrial distribution panels feeding motor control centers or transformer secondaries.

Panel fit and mounting

Footprint is 105 mm wide × 181 mm tall × 86 mm deep. The width is the critical dimension for multi-pole grouping in a distribution panel — three of these side-by-side eat 315 mm of DIN-rail or mounting-plate width. Depth of 86 mm leaves clearance for rear-connected busbars or cable ladders behind the panel door. Rated insulation voltage Ui is 800 V, so the breaker is suitable for 690 V line-to-line systems common in heavy industrial installations. Maximum power loss at rated current is 25.5 W — factor that into enclosure thermal rise calculations if the panel is tightly packed.

Lifecycle and sourcing reality

The basic switch (the breaker without accessories) is order code 3VA2116-5HN36-0AA0; the integrated auxiliary trip module is 3VA9688-0BL33. Both are current-production accessories that share the same lifecycle status.

Trip unit and release configuration

The ETU350 is an electronic trip unit — it provides adjustable long-time, short-time, instantaneous, and ground-fault protection curves. No undervoltage release is fitted on this variant; the only auxiliary release is the shunt trip (STL), which fires on a separate voltage trigger signal. No communication module, phase-failure detection, or ground-fault monitoring is included — this is a straight line-protection breaker with remote trip capability. Ambient operating range is -25 °C to +70 °C; storage range is -40 °C to +80 °C. The breaker does not include a mechanical trip indicator — status is read from the auxiliary switches or the handle position.

Frequently asked questions

Where can I buy 3VA2116-5HN36-0KC0 and get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of 3VA2116-5HN36-0KC0?

Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. These are the interrupting ratings across common industrial voltage levels.

Does 3VA2116-5HN36-0KC0 include a shunt trip?

Yes, it includes a shunt trip (STL) auxiliary release for remote tripping. No undervoltage release is fitted. Two HQ auxiliary switches are integrated for status feedback.

MPN
3VA2116-5HN36-0KC0