Siemens 3VA2116-5JP42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5JP42-0AA0 SENTRON MCCB, 160 A, 4-Pole, ETU5

MPN3VA2116-5JP42-0AA0
Active

Siemens SENTRON 3VA2116-5JP42-0AA0, molded case circuit breaker, 4-pole, 160 A, ETU550 electronic trip unit, 187 kA interrupting at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5JP42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2116-5JP42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5JP42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2116-5JP42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5JP42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-5JP42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5JP42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2116-5JP42-0AA0 — 160 A, 4-Pole MCCB with ETU550

The Siemens 3VA2116-5JP42-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 160 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That's a solid 160 A at 70 °C, which means it holds its rating in a hot panel where many breakers start to step down. Four poles, with an ETU550 electronic trip unit. The neutral protection is adjustable — you can set it OFF or anywhere from 20% to 100% of the phase pickup. That's useful for 4-wire systems where you need to coordinate ground-fault or harmonic currents on the neutral. Interrupting capacity is 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. That 187 kA at 240 V puts it in the high-fault class — sized for large transformer secondaries or busway feeds where available fault current is substantial.

Panel Fit and Mounting

Footprint is 140 mm wide by 181 mm tall by 86 mm deep. That 86 mm depth is the dimension you check against gland-plate clearance or shallow back-panel enclosures — it's the projection behind the mounting surface. Front face carries an IP40 protection class — fine for a clean indoor panel, but not washdown. The breaker has a communication function, so you can pull trip data and status into a BMS or SCADA system without adding a separate power monitor. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. Maximum power loss is 25.5 W — factor that into your panel thermal budget if you're stacking several breakers in a sealed enclosure.

Frequently asked questions

Does 3VA2116-5JP42-0AA0 have adjustable neutral protection?

Yes, the neutral protection is adjustable OFF or from 20% to 100% of the phase pickup setting, via the ETU550 trip unit.