Skip to main content
Siemens 3VA2116-5JQ32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5JQ32-0AJ0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5JQ32-0AJ0

Siemens SENTRON 3VA2116-5JQ32-0AJ0, molded case circuit breaker, 3-pole, 160 A rated, 187 kA interrupting at 240 V, line protection design, communication function, trip indicator.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5JQ32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11

Ratings

3VA2116-5JQ32-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5JQ32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2116-5JQ32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5JQ32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2116-5JQ32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5JQ32-0AJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what the ratings mean for fit

The Siemens 3VA2116-5JQ32-0AJ0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels. Its 160 A full-scale rating holds steady across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel layout in warm enclosures. The 3-pole construction and interrupting ratings of 187 kA at 240 V and 121 kA at 415 V mean it can clear high-fault currents on the line side without upstream coordination issues. The communication function (likely via the 3VA COM module) allows remote monitoring and trip-event logging, useful for a managed power distribution scheme.

Physical footprint and panel integration

At 105 mm wide, 181 mm tall, and 86 mm deep, this MCCB fits standard SENTRON 3VA mounting footprints. The depth is the dimension that matters for gland-plate clearance and busbar reach — 86 mm (3.39 in) is shallow enough for most 600 mm deep enclosures. The auxiliary switch configuration (2 auxiliary switches + 1 trip alarm switch HP) provides status feedback without adding external relays.

MPN
3VA2116-5JQ32-0AJ0