Siemens 3VA2116-5JQ32-0BH0 — Molded Case Circuit Breakers (MCCB)

3VA2116-5JQ32-0BH0 SENTRON MCCB, 160 A, 3-pole, line protect

MPN3VA2116-5JQ32-0BH0

Siemens SENTRON 3VA2116-5JQ32-0BH0, molded case circuit breaker (MCCB), 3-pole, 160 A rated, line protection, undervoltage release, auxiliary switches, communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5JQ32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2116-5JQ32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.28 W

Protection & Trip Unit

3VA2116-5JQ32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2116-5JQ32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5JQ32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2116-5JQ32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5JQ32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2116-5JQ32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 160 A across the full ambient range from 40 °C to 70 °C with no derating needed. It breaks up to 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — giving you selectivity headroom across common distribution voltages without oversizing the frame. The adjustable overcurrent trip range spans 240 A to 1 600 A, with a 32 A initial value and 160 A full-scale setting, so it can be tuned to protect a transformer, feeder, or busway rather than a single load. It ships with an undervoltage release (UVR) and a complement of 2 auxiliary switches plus 1 trip alarm switch (HQ design), and includes onboard communication — so it's ready for remote monitoring and emergency trip in a safety circuit.

At 105 mm wide, 181 mm tall, and 86 mm deep, it fits the standard SENTRON 3VA panel footprint — same bus-bar spacing and mounting hole pattern as the rest of the 3VA family. The 28 W maximum power loss means you can pack it into a moderate-density enclosure without forced cooling, but keep an eye on the internal ambient if you're stacking breakers. Operating range is -25 °C to 70 °C; storage from -40 °C to 80 °C. That's enough for unheated electrical rooms or outdoor enclosures in temperate climates, but if the panel sees sustained below-freezing startup, the UVR coil must be verified to pull in at the available voltage.

Frequently asked questions

Where can I buy 3VA2116-5JQ32-0BH0 and what is the lead time?

This MCCB is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figure or lead-time number is published here.

What is the breaking capacity of 3VA2116-5JQ32-0BH0 at 240 V?

It breaks 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

What is the depth of 3VA2116-5JQ32-0BH0?

The depth is 86 mm (3.39 in).

What is the width of 3VA2116-5JQ32-0BH0?

The width is 105 mm (4.13 in).

Does 3VA2116-5JQ32-0BH0 include an undervoltage release?

Yes, it includes an undervoltage release (UVR) as standard, plus 2 auxiliary switches and 1 trip alarm switch.

MPN
3VA2116-5JQ32-0BH0