Skip to main content
Siemens 3VA2116-5JQ32-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5JQ32-0KH0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5JQ32-0KH0

Siemens SENTRON 3VA2116-5JQ32-0KH0, 3-pole molded case circuit breaker, 160 A continuous, 187 kA at 240 V, line protection design, 86 mm depth, 105 mm width, 181 mm height.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5JQ32-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165JQ320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2116-5JQ32-0KH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5JQ32-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2116-5JQ32-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5JQ32-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2116-5JQ32-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5JQ32-0KH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers

The Siemens SENTRON 3VA2116-5JQ32-0KH0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous at 40 °C, with a full-scale value of 160 A. It carries 187 kA interrupting capacity at 240 V, stepping down to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — so it handles high-fault utility feeds at lower voltages while still breaking moderate faults at 690 V. The breaker is designed for line protection and includes a shunt trip (STL) plus two auxiliary switches and one trip alarm switch (HQ). It also has a trip indicator and a voltage trigger, making it suitable for remote signaling and undervoltage supervision in a control panel.

Panel fit and integration

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or screw-mount panel layouts. The 86 mm depth leaves room for wiring gutters in a 200 mm deep enclosure. Operating temperature range is -25 °C to 70 °C, with storage from -40 °C to 80 °C. Power loss at full load is 25.5 W maximum — a factor for thermal management in a sealed cabinet.

Frequently asked questions

What is the interrupting capacity of 3VA2116-5JQ32-0KH0 at 240 V?

187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

What auxiliary switches come with this MCCB?

It includes two auxiliary switches and one trip alarm switch (HQ), plus a shunt trip (STL) for remote tripping.

Where can I buy 3VA2116-5JQ32-0KH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2116-5JQ32-0KH0