Siemens 3VA2116-5JQ36-0AK0 SENTRON MCCB, 160 A, 3-pole

MPN3VA2116-5JQ36-0AK0

Siemens SENTRON 3VA2116-5JQ36-0AK0, molded case circuit breaker (MCCB), 3-pole, adjustable thermal-magnetic trip 32–256 A, rated 160 A at 40–70 °C, breaking capacity 121 kA at 415 V, with communication function and auxiliary/trip alarm switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-5JQ36-0AK0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165JQ360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2116-5JQ36-0AK0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-5JQ36-0AK0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2116-5JQ36-0AK0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-5JQ36-0AK0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2116-5JQ36-0AK0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-5JQ36-0AK0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens SENTRON 3VA2116-5JQ36-0AK0 is a 3-pole molded case circuit breaker (MCCB) with an adjustable thermal-magnetic trip unit covering 32 A to 256 A, factory-set at 160 A. That 160 A rating holds across the full ambient range of 40 °C to 70 °C — no derating needed in a warm panel. Breaking capacity at 415 V is 121 kA, which covers most industrial fault levels upstream of a transformer or generator. At 240 V it rises to 187 kA; at 690 V it drops to 3.7 kA — the part is sized for low-voltage distribution, not 690 V motor circuits. It ships with one auxiliary switch, one trip alarm switch, and one electrical alarm switch (HQ type), plus a communication function for remote status or integration into a BMS or PLC. No undervoltage release is fitted on this variant.

Where it fits in the panel

The breaker measures 86 mm deep, 105 mm wide, and 181 mm tall — a standard 3-pole MCCB footprint for DIN-rail or screw-mount panel integration. The 86 mm depth leaves clearance for rear-connected busbars in a typical distribution cabinet. Rated insulation voltage is 800 V, so it can be used in 480 V or 600 V systems with full voltage margin. Storage temperature range of -40 °C to 80 °C means it can sit in an unheated warehouse before commissioning.

Frequently asked questions

How do I get current pricing and availability for 3VA2116-5JQ36-0AK0?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time.

What are the key ratings of 3VA2116-5JQ36-0AK0?

Rated current 160 A (adjustable 32–256 A), breaking capacity 121 kA at 415 V, 3-pole, with communication function and auxiliary/trip alarm switches.

Will 3VA2116-5JQ36-0AK0 drop into a panel that was specified around 5SQ2370-2YA05 without rewiring?