Skip to main content
Siemens 3VA2116-5KP32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5KP32-0AJ0 SENTRON MCCB, 160 A, 187 kA

MPN3VA2116-5KP32-0AJ0

Siemens SENTRON 3VA2, molded case circuit breaker, 3-pole, 160 A, ETU850 electronic trip unit, 187 kA interrupting capacity at 240 V, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5KP32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA21165KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2116-5KP32-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5KP32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2116-5KP32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5KP32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3
3VA2116-5KP32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5KP32-0AJ0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2116-5KP32-0AJ0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 160 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Interrupting capacity hits 187 kA at 240 V, 121 kA at 415/440 V, and still holds 75.6 kA at 500 V — high enough for most main feeder or large motor branch applications where fault current is substantial.

The interrupting ratings tell you the maximum fault current the breaker can safely clear at each voltage: 187 kA at 240 V is typical for a main on a large low-voltage transformer; 121 kA at 415 V covers most industrial distribution; the drop to 3.7 kA at 690 V means this frame is not intended for 690 V main service — it's a 480 V class device. The ETU850 trip unit gives you curve shaping (LSIG) and communication, so it's suited for selective coordination studies and remote trip diagnostics.

Panel integration

Front IP40 protection means it's splash-protected on the face. The ETU850 supports communication, so plan for a communication cable route to the panel controller. The trip indicator is visible on the front.

Frequently asked questions

What trip unit does this MCCB use?

It uses the ETU850 electronic trip unit, which provides adjustable LSIG protection and communication capability.

MPN
3VA2116-5KP32-0AJ0