Skip to main content
Siemens 3VA2116-5KP32-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5KP32-0KH0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2116-5KP32-0KH0

Siemens SENTRON 3VA2116-5KP32-0KH0, molded case circuit breaker, 160 A continuous, 3-pole, 187 kA at 240 V, line protection design with communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5KP32-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21165KP320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2116-5KP32-0KH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5KP32-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-5KP32-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5KP32-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3
3VA2116-5KP32-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5KP32-0KH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2116-5KP32-0KH0 — 160 A MCCB, 3-Pole, Line Protection

The Siemens SENTRON 3VA2116-5KP32-0KH0 is a molded case circuit breaker (MCCB) rated for 160 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel design in warm enclosures. Interrupting capacity reaches 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 690 V figure is low, so verify system SCCR if the breaker is applied at that voltage level.

The breaker measures 105 mm wide, 181 mm high, and 86 mm deep — a standard SENTRON 3VA frame size that fits existing switchboard cutouts and DIN-rail adapter plates. At 25.5 W maximum power loss, ventilation in the enclosure should be considered if multiple breakers are ganged; the operating temperature range of -25 °C to 70 °C covers most industrial environments.

Auxiliary and Communication Options

A communication function is present.

Frequently asked questions

Does 3VA2116-5KP32-0KH0 include a shunt trip?

Yes, it includes a shunt trip (STL) auxiliary release plus two auxiliary switches and one trip alarm switch.

MPN
3VA2116-5KP32-0KH0