Skip to main content
Siemens 3VA2116-5KQ36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5KQ36-0AA0 SENTRON MCCB, 160 A, 3-Pole, ETU8

MPN3VA2116-5KQ36-0AA0
Active

Siemens SENTRON 3VA2116-5KQ36-0AA0, molded case circuit breaker, 3-pole, 160 A, ETU860 electronic overcurrent release, line protection, 187 kA at 240 V, 121 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5KQ36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2116-5KQ36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5KQ36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
3VA2116-5KQ36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5KQ36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-5KQ36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5KQ36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2116-5KQ36-0AA0 is a 3-pole molded case circuit breaker rated for 160 A continuous current across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling. It carries an ETU860 electronic overcurrent release, which gives you adjustable long-time, short-time, instantaneous, and ground-fault protection curves. The interrupting ratings are the headline: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

Depth of 86 mm means it clears most standard gland plates and backpan covers without a spacer.

Protection and release features

This is a line-protection breaker — no undervoltage release fitted, no voltage-trip module. It does include a communication function and a ground-fault monitoring version configured for summation current formation on the L-conductor. The ETU860 release supports adjustable settings for LSIG (long-time, short-time, instantaneous, ground) protection. Maximum power loss is 25.5 W — that's the heat you need to vent inside the enclosure at full load.

Environmental range

The 160 A rating holds flat across the entire operating range — no derating curve to track.

Frequently asked questions

Where can I buy 3VA2116-5KQ36-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2116-5KQ36-0AA0 at 415 V?

The breaking capacity is 121 kA at 415 V, and the same rating applies at 440 V.

What overcurrent release does this MCCB use?

It uses the ETU860 electronic overcurrent release, which provides adjustable LSIG protection curves.

Does 3VA2116-5KQ36-0AA0 include ground-fault monitoring?

Yes, it has a ground-fault monitoring version configured for summation current formation on the L-conductor.

MPN
3VA2116-5KQ36-0AA0