Skip to main content
Siemens 3VA2116-5KQ46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-5KQ46-0AA0 SENTRON MCCB, 160 A, 4P, ETU860

MPN3VA2116-5KQ46-0AA0
Active

Siemens SENTRON 3VA2, molded case circuit breaker, 4-pole, 160 A, ETU860 electronic trip unit, 187 kA at 240 V AC, IP40 front, communication capable.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-5KQ46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2116-5KQ46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-5KQ46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2116-5KQ46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-5KQ46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-5KQ46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-5KQ46-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

160 A MCCB with ETU860 — selectivity and communication in a 4-pole frame

The interrupting ratings are the headline: 187 kA at 240 V AC, 121 kA at 415 V and 440 V AC, 75.6 kA at 500 V AC, and 3.7 kA at 690 V AC — figures that cover most industrial service-entrance and feeder applications.

The drop to 75.6 kA at 500 V and 3.7 kA at 690 V is typical for this frame size; at 690 V you are near the upper voltage limit, so verify the available fault current at that voltage against the 3.7 kA ceiling.

Integration notes

The 3VA2116-5KQ46-0AA0 mounts in a standard panel or enclosure footprint. Dimensions are 181 mm height, 140 mm width, and 86 mm depth. The ETU860 trip unit is adjustable, and the N-conductor protection can be set to OFF or between 20 % and 100 % of the phase current. The communication function allows remote monitoring and control via the SENTRON bus system. Maximum power loss is 25.5 W.

Frequently asked questions

How do I get current pricing and availability for 3VA2116-5KQ46-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is 3VA2116-5KQ46-0AA0's interrupting rating at 415 V?

The interrupting rating at 415 V AC is 121 kA.

What trip unit does 3VA2116-5KQ46-0AA0 use?

It uses the ETU860 electronic trip unit with adjustable N-conductor protection (OFF, 20 % to 100 %).

MPN