Skip to main content
Siemens 3VA2116-6HL32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6HL32-0DA0 SENTRON MCCB, 160 A, 3-Pole, Line

MPN3VA2116-6HL32-0DA0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2116-6HL32-0DA0, 3-pole, 160 A rated continuous current, line protection version with ETU320 electronic trip unit, breaking capacity 242 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-6HL32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2116-6HL32-0AA0
3VA2116-6HL32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C154 A
Current at 60 °C148 A
Current at 65 °C142 A
Current at 70 °C136 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V5 kA
Power loss, max.28 W
3VA2116-6HL32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2116-6HL32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-6HL32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-6HL32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-6HL32-0DA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2116-6HL32-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 160 A at ambient temperatures up to 50 °C — meaning it can carry full load without derating in a typical 40 °C panel, and only begins to step down above 55 °C (154 A at 55 °C, 148 A at 60 °C, 142 A at 65 °C, 136 A at 70 °C). Breaking capacity hits 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 5 kA at 690 V — these are the maximum fault currents the breaker can safely interrupt at each voltage level, critical for confirming SCCR compliance in high-fault panels like transformer secondaries or large motor control centers. Rated insulation voltage Ui is 800 V, and the operating temperature range spans -25 °C to 70 °C, with storage from -40 °C to 80 °C — the storage limits govern handling during transport, not running conditions.

Lifecycle stage is marked as current — meaning this is an active, in-production part from Siemens. No phase-out or last-time-buy notice applies.

Panel integration and mechanical fit

Maximum power loss is 28 W — a modest thermal load for a 160 A breaker, but if multiple units are ganged in a sealed enclosure, factor the cumulative heat into the cabinet cooling budget.

MPN