Siemens 3VA2116-6HL32-0HA0 SENTRON MCCB, 160 A, 3-Pole, 242

MPN3VA2116-6HL32-0HA0

Siemens SENTRON 3VA2116-6HL32-0HA0, molded case circuit breaker, line protection, 3-pole, 160 A continuous, 242 kA interrupting at 240 V, shunt trip release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-6HL32-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21166HL320AA0
3VA2116-6HL32-0HA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-6HL32-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-6HL32-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-6HL32-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-6HL32-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-6HL32-0HA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2116-6HL32-0HA0 is a 3-pole molded case circuit breaker (MCCB) designed for line protection, rated 160 A continuous current and delivering a 242 kA interrupting capacity at 240 V. That interrupting rating drops to 187 kA at 415 V and 440 V, and 121 kA at 500 V — still high enough for most secondary distribution panels. At 690 V it's rated 3.7 kA, which narrows the application to low-fault locations on 690 V systems.

The supplied basic switch is 3VA21166HL320AA0, which means the core interrupter is the same across several 3VA2116 variants; the order code suffix adds the shunt trip and line-protection design.

Frequently asked questions

Will 3VA2116-6HL32-0HA0 drop into a panel specified around 3VA2116-5HL32-0AK0 without rewiring?

Both share the same 3-pole frame, 160 A rating, and similar interrupting capacities, but the -6HL32-0HA0 includes a shunt trip release (STL) while the -5HL32-0AK0 does not. If the original panel has no provision for the shunt trip coil wiring, the -6HL32-0HA0 will physically fit the same mounting footprint but requires an extra control circuit. Verify the auxiliary release wiring before swapping.

What is the interrupting capacity of this MCCB at 240 V?

242 kA at 240 V. At 415 V and 440 V it is 187 kA, at 500 V it is 121 kA, and at 690 V it is 3.7 kA.

Where can I buy 3VA2116-6HL32-0HA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your target quantity.

MPN
3VA2116-6HL32-0HA0