Siemens 3VA2116-6HL32-0JC0 SENTRON MCCB, 160 A, 3-Pole, 242

MPN3VA2116-6HL32-0JC0

Siemens SENTRON 3VA2116-6HL32-0JC0, molded case circuit breaker, 3-pole, 160 A continuous, breaking capacity 242 kA at 240 V, 187 kA at 415 V, 121 kA at 500 V, 3.7 kA at 690 V, with shunt trip and 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-6HL32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21166HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2116-6HL32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-6HL32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-6HL32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-6HL32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2116-6HL32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-6HL32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2116-6HL32-0JC0 is a 3-pole molded case circuit breaker rated for 160 A continuous current, designed for line protection in distribution panels and motor control centers. Its breaking capacity scales with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V — the 690 V figure tells you this breaker is sized for low-voltage distribution, not 690 V motor circuits where fault current is lower. The breaker carries a shunt trip release (STL) and two HQ auxiliary switches, so it can be wired into a safety circuit or remote-trip scheme without an add-on module.

Dimensions are 105 mm wide, 181 mm high, 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without re-drilling. Rated for continuous operation from -25 °C to 70 °C ambient; storage range -40 °C to 80 °C. Power loss at full load is 25.5 W — factor that into enclosure thermal calculations.

Frequently asked questions

Does this breaker include a shunt trip?

Yes, it is equipped with a shunt trip release (STL) and two HQ auxiliary switches, allowing remote tripping and status feedback.

MPN