Specifications

3VA2116-6HL32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21166HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2116-6HL32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-6HL32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-6HL32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-6HL32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2116-6HL32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-6HL32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2116-6HL32-0JH0 is a 3-pole molded case circuit breaker rated for 160 A continuous current at 40 °C through 70 °C — no derating needed across that span, which simplifies panel sizing in warm enclosures or near other heat sources. Breaking capacity hits 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V — so for most low-voltage distribution (240–500 V) it handles high-fault scenarios without cascading upstream.

That 105 mm width for a 3-pole MCCB is standard — drops into most DIN-rail or bolt-on panel layouts without re-drilling the gland plate. The thermal curve is flat on current — 160 A holds at every ambient up to 70 °C — so no extra headroom needed for elevated cabinet temps.

Frequently asked questions

How do I get current pricing and availability for 3VA2116-6HL32-0JH0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time; no public price or live count is carried here.

What is the continuous current rating of 3VA2116-6HL32-0JH0?

160 A continuous at ambient temperatures from 40 °C up to 70 °C — no derating required across that range.

What breaking capacity does 3VA2116-6HL32-0JH0 have at 415 V?

187 kA at 415 V — sufficient for most industrial low-voltage distribution with high fault currents.

Does 3VA2116-6HL32-0JH0 include a shunt trip?

Yes — it ships with a shunt trip release (STL) plus two auxiliary switches and one trip alarm switch.