Skip to main content
Siemens 3VA2116-6HL32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6HL32-0KA0 SENTRON MCCB, 160 A, 3-Pole

MPN3VA2116-6HL32-0KA0

Siemens SENTRON 3VA2116-6HL32-0KA0, molded case circuit breaker, 3-pole, 160 A continuous rating, line protection design, shunt trip (STL) auxiliary release, 242 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-6HL32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21166HL320AA0
3VA2116-6HL32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-6HL32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-6HL32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-6HL32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-6HL32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-6HL32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

It carries a shunt trip (STL) auxiliary release for remote tripping, and its breaking capacity reaches 242 kA at 240 V, 187 kA at 415 V, and 121 kA at 500 V — figures that govern selectivity coordination with downstream devices.

At 240 V this MCCB interrupts 242 kA. At 690 V it falls to 3.7 kA.

The 3VA2116-6HL32-0KA0 measures 105 mm wide, 181 mm tall, and 86 mm deep — a standard SENTRON 3VA frame size that mounts on a DIN rail or bolts directly into a distribution panel. The 3-pole footprint matches the common 3-pole MCCB cutout; verify the 105 mm width against your existing busbar spacing or enclosure gland plate before committing the BOM line.

Frequently asked questions

Does 3VA2116-6HL32-0KA0 have a shunt trip?

Yes, it includes a shunt trip (STL) auxiliary release for remote tripping. It does not have an undervoltage release.

MPN