Skip to main content
Siemens 3VA2116-6HL32-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2116-6HL32-0KC0 MCCB, 160 A, 242 kA

MPN3VA2116-6HL32-0KC0

Siemens SENTRON series, Molded case circuit breaker, 3VA2116-6HL32-0KC0, 3-pole, 160 A, 242 kA at 240 V, ETU320 release, shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-6HL32-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2116-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2116-6HL32-0KC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C154 A
Current at 60 °C148 A
Current at 65 °C142 A
Current at 70 °C136 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V5 kA
Power loss, max.25.5 W
3VA2116-6HL32-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2116-6HL32-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-6HL32-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2116-6HL32-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-6HL32-0KC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What this 3VA2116-6HL32-0KC0 brings to the panel

The Siemens SENTRON 3VA2116-6HL32-0KC0 is a 3-pole molded case circuit breaker (MCCB) built for line protection, carrying a rated continuous current Iu of 160 A with an ETU320 electronic trip unit. Its interrupting capacity hits 242 kA at 240 V and 187 kA at 415 V, so it handles serious fault currents without letting the arc climb upstream — that's the kind of headroom that keeps a selectivity study simple. The 160 A rating holds steady from 40 °C up to 50 °C, then derates to 154 A at 55 °C and 136 A at 70 °C — a curve you'll want to check if the panel sits near a hot motor or a sunny wall.

The breaker measures 105 mm wide, 181 mm tall, and 86 mm deep — that 86 mm depth is the dimension to watch when you're sliding it into a tight enclosure or a panel with a shallow backpan. It's a 3-pole unit rated for 800 V insulation voltage, so it fits standard 3-phase distribution panels up to 690 V line-to-line.

Frequently asked questions

Will 3VA2116-6HL32-0KC0 drop into a panel specified around 3VA1110-5EE32-0JA0?

The 3VA2116-6HL32-0KC0 is a larger frame (160 A vs the 3VA1110's lower rating) and has different trip unit and accessory configurations. Panel fit depends on the specific mounting and busbar layout; verify dimensions and wiring before substituting.

MPN
3VA2116-6HL32-0KC0