Skip to main content
Siemens 3VA2116-6HL32-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6HL32-0KH0 SENTRON MCCB, 160 A, 3-Pole, 242

MPN3VA2116-6HL32-0KH0

Siemens SENTRON 3VA2116-6HL32-0KH0, molded case circuit breaker, 3-pole, 160 A continuous, adjustable trip 240–1600 A, breaking capacity 242 kA at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-6HL32-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21166HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2116-6HL32-0KH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-6HL32-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-6HL32-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-6HL32-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2116-6HL32-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-6HL32-0KH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2116-6HL32-0KH0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous current at 40 °C, with an adjustable thermal-magnetic trip range from 240 A up to 1 600 A — so you size the trip to the load, not the other way around. Breaking capacity hits 242 kA at 240 V, 187 kA at 415 V, and still 121 kA at 500 V, meaning it clears high-fault currents on industrial distribution without cascading upstream.

The 3-pole footprint matches the 3VA2 family; if you are swapping a 3VA2116-5HL32-0AK0, check the busbar pitch and lug kit — the frame size is the same, so the mechanical drop-in is straightforward, but the trip curve and accessory wiring differ.

The adjustable trip range (240–1 600 A) covers motor feeders, transformer secondaries, and main distribution. Maximum power loss is 25.5 W, so panel ventilation is not a concern for this single unit.

Frequently asked questions

Will 3VA2116-6HL32-0KH0 drop into a panel specified around 3VA2116-5HL32-0AK0?

The frame size and 3-pole footprint are the same, so the mechanical fit is identical. The difference is in the trip curve and accessory configuration — verify the shunt trip wiring and auxiliary switch count before swapping.

MPN
3VA2116-6HL32-0KH0