Skip to main content
Siemens 3VA2116-6HM36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6HM36-0AA0 SENTRON MCCB, 160 A, 3-Pole, 242

MPN3VA2116-6HM36-0AA0
Active

Siemens SENTRON 3VA2116-6HM36-0AA0, molded case circuit breaker, 3-pole, 160 A continuous, ETU330 electronic trip unit, line protection variant.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-6HM36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2116-6HM36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-6HM36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L-conductor

Construction & Connection

3VA2116-6HM36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-6HM36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-6HM36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-6HM36-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this 3VA2 frame delivers

The Siemens 3VA2116-6HM36-0AA0 is a SENTRON molded case circuit breaker (MCCB) in a 3-pole, 160 A continuous-current configuration, fitted with an ETU330 electronic trip unit and designated for line protection duty. Rated insulation voltage Ui is 800 V, and the interrupting capacity reaches 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V — giving the breaker substantial fault-clearing headroom across common industrial voltage levels. The 160 A rating holds flat across the full operating temperature range from 40 °C to 70 °C, so no derating is needed for warm enclosures up to that limit. Maximum power loss is 25.5 W, and front-face protection is IP40 — suitable for panel-mount applications where the breaker is behind a closed door.

Dimensions and panel fit

The breaker occupies 105 mm width, 181 mm height, and 86 mm depth (4.13 × 7.13 × 3.39 in), which is the standard 3VA2 frame footprint for this current class. Mounts on a DIN rail or direct-panel via the 3VA accessory kit; the 86 mm depth leaves room for rear-connected busbars or cable lugs in a typical distribution panel.

MPN
3VA2116-6HM36-0AA0