Skip to main content
Siemens 3VA2116-6HN32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6HN32-0AB0 SENTRON MCCB, 160 A, 3-Pole, ETU3

MPN3VA2116-6HN32-0AB0

Siemens SENTRON 3VA2116-6HN32-0AB0, molded case circuit breaker, 3-pole, 160 A, ETU350 electronic trip unit, line protection, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-6HN32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA21166HN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2116-6HN32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-6HN32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2116-6HN32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-6HN32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2116-6HN32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-6HN32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for high-fault panel feeds

The Siemens SENTRON 3VA2116-6HN32-0AB0 is a 3-pole molded case circuit breaker (MCCB) rated 160 A continuous at 40 °C, carrying a line-protection designation and an ETU350 electronic trip unit. Its interrupting capacity hits 242 kA at 240 V and 187 kA at 415 V — figures that put it in the high-fault tier, sized for main feeders in industrial switchboards where available fault current exceeds what a standard MCCB can clear. The ETU350 release provides adjustable long-time, short-time, and instantaneous protection bands, which is the deciding factor for selective coordination downstream. With no undervoltage release, no voltage trigger, and no communication function, this is a straight power-feed breaker — no auxiliary logic riding on it.

Footprint and panel fit

Dimensions: 181 mm high, 105 mm wide, 86 mm deep. The 105 mm width is the standard 3-pole MCCB footprint for this frame size — it occupies the same panel cutout as other 3VA2 160 A frames. The 86 mm depth means it clears a 100 mm deep enclosure with room for rear-connected busbars or a cable entry gland plate. IP40 on the front face; the breaker is intended for indoor panel mounting, not washdown zones.

Thermal performance across the range

Rated 160 A continuously from 40 °C through 70 °C ambient — no derating needed up to that ceiling. Power loss at full load is 25.5 W maximum. Storage range spans -40 °C to 80 °C, operating range -25 °C to 70 °C. The auxiliary contact version ships with 2 HP auxiliary switches, which is the standard complement for status feedback to a PLC or SCADA input.

Frequently asked questions

Where can I buy 3VA2116-6HN32-0AB0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the interrupting capacity of 3VA2116-6HN32-0AB0?

242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V.

MPN
3VA2116-6HN32-0AB0