Siemens 3VA2116-6HN32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6HN32-0AJ0 SENTRON MCCB, 160 A, 3-Pole, ETU3

MPN3VA2116-6HN32-0AJ0

Siemens SENTRON 3VA2116-6HN32-0AJ0, molded case circuit breaker, 3-pole, 160 A, ETU350 electronic trip unit, 242 kA at 240 V, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-6HN32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2116-6HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11

Ratings

3VA2116-6HN32-0AJ0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C154 A
Current at 60 °C148 A
Current at 65 °C142 A
Current at 70 °C136 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V5 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-6HN32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350

Construction & Connection

3VA2116-6HN32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-6HN32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2116-6HN32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-6HN32-0AJ0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2116-6HN32-0AJ0 is a 3-pole molded case circuit breaker (MCCB) rated for a continuous current Iu of 160 A, carrying an ETU350 electronic trip unit for line protection. This is the breaker you spec when you need adjustable overload and short-circuit protection in a compact 105 mm wide footprint — common in distribution panels feeding motor control centers or as a main disconnect for sub-distribution boards.

Interrupting capacity and what it means for your fault level

At 240 V this breaker interrupts 242 kA — that's the highest short-circuit current it can safely clear without welding contacts or rupturing the case. At 415 V and 440 V it still handles 187 kA; at 500 V it drops to 121 kA; at 690 V it's rated 5 kA. For a 160 A frame, those are high-interrupt ratings, meaning this unit belongs in a high-fault location — close to a transformer or a large service entrance — where available fault current can exceed 100 kA. The 690 V rating is low enough that you'd verify the actual fault current at that voltage before committing.

Thermal derating — don't lose capacity in a hot panel

The 160 A rating holds steady from 40 °C through 50 °C ambient. At 55 °C you derate to 154 A, at 60 °C to 148 A, at 65 °C to 142 A, and at 70 °C to 136 A. If this breaker sits in a sealed enclosure near other heat sources, check the actual internal ambient — you may need to upsize the frame or provide forced ventilation to keep the full 160 A. The maximum operating temperature is 70 °C; storage range is -40 °C to 80 °C.

Trip unit and auxiliary contacts

The ETU350 is an electronic trip unit — adjustable overload (Ir), short-time (Isd), and instantaneous (Ii) settings via DIP switches or rotary dials on the front face. It gives you coordination flexibility that a fixed thermal-magnetic cannot. The breaker ships with 2 auxiliary switches plus 1 trip alarm switch (HP type), so you get status feedback for SCADA or a local annunciator without adding an external accessory block. No undervoltage release, no shunt trip, no ground-fault monitoring on this variant — those are add-on modules if needed.

Physical fit and panel integration

Dimensions are 105 mm wide by 181 mm high by 86 mm deep. That 105 mm width is standard for a 160 A frame in the 3VA platform — it mounts via screw terminals or rear-connect busbars onto a DIN rail or a mounting plate. The front face carries IP40 protection, so it's fine for a typical IP54 or IP65 enclosure interior; just don't expose the front to direct hose-down. Three poles, line side on top, load side on bottom — straightforward bus or cable connection.

Frequently asked questions

What is the interrupting capacity of 3VA2116-6HN32-0AJ0 at 240 V?

At 240 V the interrupting capacity is 242 kA; at 415 V and 440 V it is 187 kA; at 500 V it is 121 kA; at 690 V it is 5 kA.

What trip unit does 3VA2116-6HN32-0AJ0 use?

It uses the ETU350 electronic trip unit, which provides adjustable overload, short-time, and instantaneous protection settings.

Where can I buy 3VA2116-6HN32-0AJ0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the rated continuous current of 3VA2116-6HN32-0AJ0?

The rated continuous current Iu is 160 A, which holds steady up to 50 °C ambient before derating begins.