Skip to main content
Siemens 3VA2116-6HN32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6HN32-0DA0 SENTRON MCCB, 160 A, 3-Pole, 242

MPN3VA2116-6HN32-0DA0

Siemens SENTRON 3VA2116-6HN32-0DA0, molded case circuit breaker, 3-pole, 160 A rated continuous current, 242 kA breaking capacity at 240 V AC, line protection design with undervoltage release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-6HN32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21166HN320AA0

Ratings

3VA2116-6HN32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.28 W

Protection & Trip Unit

3VA2116-6HN32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2116-6HN32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-6HN32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-6HN32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-6HN32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers on the line

The Siemens SENTRON 3VA2116-6HN32-0DA0 is a 3-pole molded case circuit breaker rated for 160 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up. Its interrupting capacity hits 242 kA at 240 V AC and still holds 187 kA at 415 V, so it handles high-fault utility feeds without cascading upstream. The built-in undervoltage release (UVR) trips the breaker if control voltage drops, which is a common requirement for emergency-stop circuits and safety disconnects.

Breaking capacity and selectivity headroom

At 240 V the 242 kA rating is well above typical service-entrance fault levels, giving you selectivity headroom for downstream branch breakers. At 690 V the rating drops to 3.7 kA — still adequate for most 690 V motor circuits, but verify coordination if the fault current exceeds that. The 800 V rated insulation voltage (Ui) means the breaker can be used in 480 V and 600 V class systems with margin.

Panel fit and integration

The breaker measures 105 mm wide, 181 mm tall, and 86 mm deep — a standard 3-pole MCCB footprint for DIN-rail or panel-mount enclosures. The undervoltage release is factory-installed; no separate module to order. Line protection design means it is set up for feeder duty out of the box, not motor protection (no thermal-magnetic adjustment range). If you need adjustable overloads, look at the 3VA2 with electronic trip units.

Frequently asked questions

Where can I buy 3VA2116-6HN32-0DA0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2116-6HN32-0DA0 at different voltages?

242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V.

Does 3VA2116-6HN32-0DA0 include an undervoltage release?

Yes, it comes with a factory-installed undervoltage release (UVR) for tripping on control-voltage loss.

MPN
3VA2116-6HN32-0DA0