Siemens 3VA2116-6JP42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6JP42-0AA0 SENTRON MCCB, 160A, 4-Pole, ETU55

MPN3VA2116-6JP42-0AA0
Active

Siemens SENTRON 3VA2116-6JP42-0AA0, molded case circuit breaker, 4-pole, 160 A continuous, ETU550 electronic trip unit, line protection version, with communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-6JP42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2116-6JP42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-6JP42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2116-6JP42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-6JP42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-6JP42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-6JP42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens 3VA2116-6JP42-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 160 A continuous current across the full operating temperature range from -25 °C to 70 °C — no derating needed up to 70 °C ambient, which is rare for a 160 A frame and saves you from having to oversize the breaker for warm panels. It carries a 4-pole configuration with an ETU550 electronic trip unit, designed for line protection duty. The ETU550 gives you adjustable long-time, short-time, instantaneous, and ground-fault settings — the kind of selectivity you need for a distribution feeder or a large motor branch circuit where coordination with downstream breakers matters. Short-circuit breaking capacity is serious: 242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. Those numbers mean this breaker can sit at the main incoming position in a high-fault panel and still clear a bolted fault without upstream coordination — it's sized for industrial service entrances or large distribution switchboards.

Mounting and integration

The 3VA2116-6JP42-0AA0 measures 181 mm high, 140 mm wide, and 86 mm deep — a 4-pole frame that fits standard MCCB mounting patterns in distribution panels. The IP40 front protection means it's fine for indoor panel mounting where no washdown or dust ingress is expected; keep it behind a gland plate or enclosure door. It ships with a communication function onboard (: yes), so you can tie it into a BMS or SCADA system for remote trip indication and power monitoring without bolting on an external module. An optional motor drive is available for remote open/close — useful for a main breaker that needs to be cycled from a control room. Maximum power loss is 25.5 W at rated current — that's the heat you need to account for in your panel thermal budget. The storage temperature range (-40 °C to 80 °C) covers cold warehouses and hot shipping containers, but the operating range (-25 °C to 70 °C) is what governs the installation environment.

Frequently asked questions

What is the breaking capacity of 3VA2116-6JP42-0AA0 at 415 V?

187 kA at 415 V AC. That's the same rating it carries at 440 V, and it drops to 121 kA at 500 V and 3.7 kA at 690 V.

Does this MCCB include a communication function?

Yes — the communication function is present. It allows remote trip indication and power data integration with a BMS or SCADA system without an add-on module.

Where can I buy the 3VA2116-6JP42-0AA0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here, but a formal RFQ will get you the real-time supply picture.

What trip unit does the 3VA2116-6JP42-0AA0 use?

The ETU550 electronic trip unit. It provides adjustable long-time, short-time, instantaneous, and ground-fault protection settings for selective coordination in distribution or motor branch circuits.

MPN
3VA2116-6JP42-0AA0