Skip to main content
Siemens 3VA2116-6JQ36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6JQ36-0AA0 SENTRON MCCB, 160 A, 3-Pole, 242

MPN3VA2116-6JQ36-0AA0
Active

Siemens SENTRON 3VA2116-6JQ36-0AA0, molded case circuit breaker, 3-pole, 160 A, ETU560 electronic trip unit, line protection version, 242 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-6JQ36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2116-6JQ36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-6JQ36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor

Construction & Connection

3VA2116-6JQ36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-6JQ36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-6JQ36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-6JQ36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

160 A MCCB with flat thermal derating and 242 kA SCCR headroom

The Siemens 3VA2116-6JQ36-0AA0 is a SENTRON molded case circuit breaker rated for 160 A continuous current (Iu) across its full ambient temperature range — it holds 160 A from 40 °C through 70 °C with no derating step, which simplifies panel sizing in warm enclosures. The 242 kA interrupting rating at 240 V gives substantial fault-current headroom for high-capacity transformer-fed distribution, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. The 3-pole frame carries an ETU560 electronic trip unit with communication function, ground-fault monitoring via summation current formation on the L-conductor, and an optional motor drive extension. Insulation voltage is rated 800 V Ui, and front-face protection is IP40.

Selectivity and coordination — what the ratings mean for your panel

The 242 kA SCCR at 240 V means this breaker safely interrupts faults up to that level without cascading upstream — critical for transformer secondary protection where available fault current is high. The 187 kA at 415 V covers the common European low-voltage distribution voltage. The 3.7 kA at 690 V is a sharp drop; if your system runs 690 V line-to-line, verify that the available fault current stays under that threshold, or upstream protection must limit it. The flat 160 A derating curve from 40 °C to 70 °C is unusual — most MCCBs begin derating above 40 °C. That gives you consistent ampacity in a hot panel without oversizing the frame.

Panel integration and mounting

The 3VA2116-6JQ36-0AA0 measures 105 mm wide, 181 mm high, and 86 mm deep — a 3-pole frame that fits standard MCCB panel cutouts. Front-face protection is IP40, suitable for enclosed distribution boards where no washdown exposure occurs. The optional motor drive extension allows remote closing or opening. The ETU560 electronic trip unit supports communication, so you can integrate status and trip data into a BMS or PLC over the breaker's communication interface.

Frequently asked questions

What is the closest functional second-source for 3VA2116-6JQ36-0AA0?

The peer MPNs 5SQ2370-2YA05, 5SQ2370-2YA04, and 5SQ2370-2YA01 are functionally similar SENTRON 3VA breakers, but they may differ in trip unit configuration, communication options, or accessory fit. Verify the specific trip curve and ground-fault monitoring version before substituting — the ETU560 release with summation current ground-fault monitoring on this unit is a specific configuration.

What compliance documentation is available for 3VA2116-6JQ36-0AA0?

As a Siemens SENTRON product, this MCCB carries the expected IEC 60947-2 certification for molded case circuit breakers. RoHS and REACH compliance declarations are standard from Siemens for current-production SENTRON devices. Specific UL listing status should be confirmed against the exact catalog number at quote time.

Where can I buy 3VA2116-6JQ36-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3VA2116-6JQ36-0AA0