Siemens 3VA2116-6JQ46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2116-6JQ46-0AA0 SENTRON MCCB, 160 A, 4-Pole, 86 m

MPN3VA2116-6JQ46-0AA0
Active

Siemens SENTRON 3VA2116-6JQ46-0AA0, molded case circuit breaker, 4-pole, 160 A continuous rated current, 242 kA breaking capacity at 240 V, line protection design with communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2116-6JQ46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2116-6JQ46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W

Protection & Trip Unit

3VA2116-6JQ46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes

Construction & Connection

3VA2116-6JQ46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2116-6JQ46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2116-6JQ46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2116-6JQ46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Product identity and key ratings

The Siemens SENTRON 3VA2116-6JQ46-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for line protection. Its continuous current rating is 160 A, with an adjustable overload trip range from 240 A minimum to 1 600 A maximum — meaning the breaker can be coordinated to protect feeders or large branch circuits within that window. Breaking capacity varies sharply by system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. That 690 V figure is low enough that the breaker is effectively a 500 V-class device for high-fault applications; at 690 V the available fault current must be verified against the 3.7 kA limit. The insulation voltage is rated 800 V, so the breaker can be applied in 690 V systems where the upstream transformer neutral is solidly grounded, provided the fault current at that voltage stays within the 3.7 kA interrupting rating.

Selectivity and coordination

The adjustable overload range (240 A minimum to 1 600 A maximum) allows this 160 A frame to be set for selective coordination with downstream breakers. The 160 A continuous rating at 40 °C through 70 °C — flat across the entire temperature band — means no derating is needed in warm enclosures, a practical advantage for panel builders who cannot guarantee ambient below 40 °C. Power loss is 25.5 W maximum at rated current. That figure feeds the enclosure thermal budget; for a multi-breaker lineup, summing the losses determines whether forced ventilation is required.

Lifecycle and sourcing

The 3VA2116-6JQ46-0AA0 carries communication function and summation-current ground-fault monitoring (L + N conductor), features that differentiate it from simpler frame variants. If the customer's approved manufacturer list specifies these options, no deviation is needed.

Panel fit and environmental limits

Dimensions are 86 mm depth, 140 mm width, 181 mm height. The 140 mm width is the standard 4-pole MCCB footprint for this frame size; verify the panel cutout and bus-bar spacing against these figures before committing the BOM line. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The storage minimum is the handling limit — the breaker can be warehoused in unheated facilities, but commissioning below -25 °C is not supported.

Frequently asked questions

How do I get current pricing and availability for 3VA2116-6JQ46-0AA0?

Pricing and availability are confirmed at quote time. Submit an RFQ for this order code; the response will include current market pricing and lead time from our supply network.

What is 3VA2116-6JQ46-0AA0's listed depth?

The depth is 86 mm (3.39 in). Combined with the 140 mm width and 181 mm height, this defines the panel cutout and enclosure clearance required.

Will 3VA2116-6JQ46-0AA0 drop into a panel specified around 3VA2116-5JP32-0AE0 without rewiring?

Both are 4-pole SENTRON 3VA frame breakers with the same 160 A continuous rating and identical physical footprint (86 mm depth, 140 mm width, 181 mm height). The 6JQ46 variant adds communication function and summation-current ground-fault monitoring; if those features are not required by the customer's AML, the 5JP32 may be an approved alternate — but a written deviation is needed before substituting on a customer-specified BOM.

MPN
3VA2116-6JQ46-0AA0