Skip to main content
Siemens 3VA2116-7HL32-0AA0 — Molded Case Circuit Breakers (MCCB)

3VA2116-7HL32-0AA0 SENTRON MCCB, 160 A, 3-Pole, ETU320

MPN3VA2116-7HL32-0AA0
Active

Siemens SENTRON 3VA series, 3VA2116-7HL32-0AA0, a 3-pole molded case circuit breaker (MCCB) rated 160 A continuous with ETU320 electronic trip unit, line protection design.

$401.32Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2116-7HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2116-7HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.25.5 W
3VA2116-7HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2116-7HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2116-7HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2116-7HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2116-7HL32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

160 A continuous, ETU320 trip — the rating that governs the BOM line

The Siemens SENTRON 3VA2116-7HL32-0AA0 is a 3-pole molded case circuit breaker (MCCB) carrying a continuous current rating of 160 A that holds flat across the operating temperature range — still 160 A at 70 °C (–). For a BOM freeze, that means no derate curve to manage inside a warm panel; the breaker delivers its nameplate rating up to the maximum operating temperature. The electronic trip unit is an ETU320, which is the base adjustable thermal-magnetic release in the 3VA line — line protection design, no ground-fault or communication function onboard. Breaking capacity hits 330 kA at 240 V and 242 kA at 415 V, then drops to 187 kA at 500 V and 3.7 kA at 690 V. The steep fall at 690 V is the limit of the 3VA platform in this frame size — if your fault study shows more than 3.7 kA available at 690 V, this breaker is not the coordination point.

Panel fit and mounting — 3-pole, 86 mm deep, IP40 front

The 3-pole format fits standard MCCB mounting footprints in Siemens SENTRON distribution panels or third-party enclosures with the appropriate cutout. No undervoltage release, no trip indicator, no voltage trigger — this is a bare breaker, add auxiliaries separately if the circuit requires shunt trip or alarm contacts.

Frequently asked questions

Where can I buy 3VA2116-7HL32-0AA0 and how do I get a price?

This part is sourced through independent industrial distribution. Submit an RFQ; availability and current pricing are confirmed at quote time. No stock count or price figure is published here.

What is 3VA2116-7HL32-0AA0's continuous current rating?

160 A continuous, and it holds that rating across the full operating temperature range from -25 °C to 70 °C (–,). No derate curve needed for elevated panel temperatures.

Will 3VA2116-7HL32-0AA0 drop into a panel specified around 3VA2116-5HL32-0AK0?

Physically yes — both are 3-pole SENTRON 3VA breakers with the same frame dimensions (181 x 105 x 86 mm). The difference is the trip unit: this one carries an ETU320, while the 5HL32 variant uses a different release. If the panel wiring and bus bars are sized for 160 A, the mechanical swap is direct. Confirm the trip curve coordination before substituting.

MPN
3VA2116-7HL32-0AA0